MyKooltronic Account
U
UserID
CUSTOMER NO.
COMPANY NAME
MyKooltronic Home
Update Your Account
View Orders
View Invoices
Track Shipments
View Shopping Cart
View Quote Requests (RFQ)
Logout
Cart
Your Shopping Cart
Your Cart is Empty
View Cart
RFQ
Your Quote Requests
You have no products to be quoted
View RFQ Cart
(609) 466-3400
Contact Us!
(609) 466-3400
Contact Us!
Toggle navigation
Products & Services
All Products
Air Conditioners
Centrifugal & Packaged Blowers
Fans and Fan Trays
Heat Exchangers
Custom Cooling Design
Enclosure Accessories
Spare/Replacement Parts
Contract Manufacturing Services
Industries
All Industries
Battery Energy Storage Systems
Kiosks, ATMs & Smart Lockers
Medical Technology
Wastewater & Water Treatment
Transportation
Industrial Manufacturing
Hazardous Locations
Food & Beverage
Military & Avionics
Infrastructure
Security Detection & Surveillance
Sizing
Resources
Cooling Solutions Blog
MyKooltronic Customer Portal
Product Documentation
Whitepapers
An Intro to Closed Loop Cooling
Quality & Compliance Certficates ►
ISO 9001:2015 Certificate
UL Client Test Data Program Certificate
ROHS 3 Compliance Statement
REACH Declaration
Kooltronic Quality Policy
Conflict Minerals Report
Credit Application
Credit Reference Form
About Us
About Kooltronic
News & Announcements
Eco-Friendly Practices
Interactive Timeline
Virtual Tour
Careers with Kooltronic
Contact Us
Send Us a Message
Sales Team
After Sale Kare (ASK)
RFQ Cart
MyKooltronic
Advantage Series
Air-Cooled Top-Mounted Air Conditioners (Discontinued)
Close
Image 1 of 1
Maximize image
Restore image
NEMA
TYPE 12 AND 3R
MAINTAINED
Select Model Type
Electrical (Volts/Hz):
220/50
200/50
230/60
208/60
NULL
BTU Capacity:
6000
12000
Model
NEMA
Rating
UL/CUL
Listed or
Recognized
BTU/H
Capacity
95/95
Rating
BTU/H
Ambient Temp.
Volts
Hz
Running
Amps
Approx.
Weight
°F
°C
Max./Min.
Max./Min.
lbs
kg
K2A4C6RTL
3R & 12
Recognized
6000
4600
120/0
49/-17
220/200
50
5.6/6.0
131
60
K2A4C12RTL
3R & 12
Recognized
12000
7900
125/0
52/-17
230/208
60
8.7/9.3
140
64
12000
7900
125/0
52/-17
200
50
8.5
140
64
Rating shown is for operation at maximum ambient temperature.
For Heating Amps, see Data Sheet.
TECHNICAL DATA
Model
NEMA
Rating
BTU/H
Capacity
Volts/Hz
K2A4C6RTL
3R & 12
6000
220/50V, 50Hz
UL/CUL Listed or Recognized: Recognized
95/95 BTU Rating: 4600
Ambient Max./Min. °F: 120/0
Ambient Max./Min. °C: 49/-18
Running Amps: 5.6/6.0
Approx. weight: 131 lbs. (60 kg)
K2A4C12RTL
3R & 12
12000
230/60V, 60Hz
UL/CUL Listed or Recognized: Recognized
95/95 BTU Rating: 7900
Ambient Max./Min. °F: 125/0
Ambient Max./Min. °C: 52/-18
Running Amps: 8.7/9.3
Approx. weight: 140 lbs. (64 kg)
K2A4C12RTL
3R & 12
12000
200/50V, 50Hz
UL/CUL Listed or Recognized: Recognized
95/95 BTU Rating: 7900
Ambient Max./Min. °F: 125/0
Ambient Max./Min. °C: 52/-18
Running Amps: 8.5
Approx. weight: 140 lbs. (64 kg)
Rating shown is for operation at maximum ambient temperature.
For Heating Amps, see Data Sheet.
Standard Features
Accessories & Options
Airflow Diagram
Performance
Arrangement
Similar Models
Documents
•
CFC-Free Refrigerant
CFC-free R134a Refrigerant is used
•
Closed-Loop Cooling
The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
•
Digital Temperature Display
•
Filter
All Kooltronic filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reusable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacement filters are available and can be ordered online at kooltronic.com/spareparts.
•
Head Pressure Control
A control device to minimize compressor cycling and prevent evaporator coil icing.
•
Low Ambient Kit
Maintains sufficient operating pressures when ambient temperatures drop below 50°F. Includes a compressor heater and a pressure device that senses the reduced discharge pressure and modulates the condenser blower. Effective to a minimum ambient temperature of 0°F.
•
Low Temperature Control Thermostat (except K2A4C12RTL)
•
NEMA 12 & 3R Ratings Maintained (UL50)
All units are fully gasketed for tight, leakproof installation, in compliance with the NEMA 12 and 3R Enclosure Ratings.
•
Painted Metal Grille
•
Programmable Thermostat (K2A4C12RTL)
•
UL/CUL Listed
•
Aluminum Shell
Where light weight and/or compatibility with appearance of aluminum enclosures are required. Unpainted Type 5052 is standard. Other types and ultraviolet-resistant baked powder finish are available.
•
Compressor Short Cycle Protector
Available as a Standard Feature on models with Programmable Thermostat. Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
•
Enclosure Heater
Eliminates damaging condensation, increasing reliability of electrical enclosure components.
•
Filter Recoating Adhesive
This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
•
Internal Corrosion Protection
This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
•
Lead-Lag Controller
•
Lifting Eyes
Heavy-gauge steel lifting eyes, attached to the side panels, assist in positioning units.
•
Remote Monitoring (K2A4C12RTL)
•
Remote Thermostat Relay
Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
•
Replacement Filters
All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
•
Special materials or finishes
•
Special motors, line cords or connectors
•
Stainless Steel Shell
•
Temperature Alarm
A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.
Click on image for larger view
Close
Image 1 of 1
Maximize image
Restore image
Dimensions, inches [mm], are for reference only and subject to change.
Click on image for larger view
Close
Image 1 of 1
Maximize image
Restore image
Dimensions, inches [mm], are for reference only and subject to change.
Dimensions, inches [mm], are for reference only and subject to change.
Model
Guideline
Dimensions
(H x W x D)*
CFM @0" S.P.
Rack/Top-Mount H5
12.13 x 17.25 x 22.00
0
Horizontal Super-Mini
9.06 x 14.00 x 16.00
0
Top-Mount HT4
10.25 x 17.00 x 20.00
0
Top-Mount H12
16.71 x 17.56 x 31.08
0
*See model specifics for drawings, dimensions, mounting or cutout plans.
2-D Drawing of the Mounting Plan
KA4C6-12RTL 2-D Drawing of the Mounting Plan [31Kb]
3-D Solid Model
KA4C6-12RTL 3-D Solid Model [6886Kb]
Data Sheet
RT Product Data Sheet [117Kb]
GA Drawing
Advantage RT Top-Mounted General Arrangement Drawing [79Kb]
Installation Instructions
Advantage RT Top-Mounted Installation Instructions (2 pages) [181Kb]
Literature
Air Conditioner Quick-Sheet [105Kb]
Condensate Evaporator Kits [241Kb]
Condensation and Electronics [3983Kb]
Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
Hazardous Location Series White Paper [234Kb]
Increasing the Lifespan and Reliability of Electrical Components [212Kb]
Slimkool Series Flyer [584Kb]
Kooltronic Custom Capabilities Flyer [2194Kb]
Kooltronic Custom Cooling Medical Flyer [211Kb]
Kooltronic Design Guide/Catalog (220 pages) [229400Kb]
Kooltronic Refrigeration System Manufacturing [55Kb]
Kooltronic Standard Warranty [55Kb]
Kooltronic Unit Longevity Press Release [167Kb]
NEMA Enclosure Ratings [91Kb]
Short-Form Catalog (16 pages) [897Kb]
Airflow Switch Data Sheet [159Kb]
Laboratory Environmental Testing Services [157Kb]
Powder Paint Application Facilities Flyer [165Kb]
Operator's Manual
Advantage RT Top-Mounted Operator's Manual (Pre-Dixell) [2312Kb]
Advantage RT Top-Mounted Operator's Manual (w/Dixell) [675Kb]
KLLC100 Lead-Lag Controller (Discontinued) [38Kb]
KLLC480 Lead-Lag Controller [79Kb]
Wiring Diagram
K_A3C6RTL & K_A3C12RTL Wiring Diagram (Ladder) [46Kb]
K_A4C3RTL Wiring Diagram (Ladder) [57Kb]
K2A3C6RTL & K2A3C12RTL Wiring Diagram (Point-to-Point) [62Kb]
K2A4C12RTL Wiring Diagram (Ladder) (w/DIXELL) [47Kb]
K2A4C12RTL Wiring Diagram (Point-to Point) (w/DIXELL) [58Kb]
K2A4C6RTL Wiring Diagram (Point-to-Point) [59Kb]
K2A4C6RTL Wiring Diagram (Point-to-Point) [57Kb]
KA4C12RTL & KA4C12RTLY Wiring Diagram (Ladder) [54Kb]
KA4C12RTL & KA4C12RTLY Wiring Diagram (Point-to-Point) [57Kb]
KA4C12RTL Wiring Diagram (Ladder) [54Kb]
KA4C12RTL Wiring Diagram (Point-to-Point) [58Kb]
KA4C12RTL Wiring Diagram (Point-to-Point) [61Kb]
KA4C3RTL Wiring Diagram (Point-to-Point) [62Kb]
KA4C6RTL Wiring Diagram (Ladder) [56Kb]
KA4C6RTL Wiring Diagram (Ladder) [54Kb]
KA4C6RTL Wiring Diagram (Point-to-Point) [59Kb]
KA4C6RTLDK Wiring Diagram (Point-to-Point) [62Kb]
KA4C6RTLK Wiring Diagram (Point-to-Point) [58Kb]
Many popular units are available as 3D solid models for customer system integration. Contact Kooltronic for details
.