MyKooltronic Account
U
UserID
CUSTOMER NO.
COMPANY NAME
MyKooltronic Home
Update Your Account
View Orders
View Invoices
Track Shipments
View Shopping Cart
View Quote Requests (RFQ)
Logout
Cart
Your Shopping Cart
Your Cart is Empty
View Cart
RFQ
Your Quote Requests
You have no products to be quoted
View RFQ Cart
(609) 466-3400
Contact Us!
(609) 466-3400
Contact Us!
Toggle navigation
Products & Services
All Products
Air Conditioners
Centrifugal & Packaged Blowers
Fans and Fan Trays
Heat Exchangers
Custom Cooling Design
Enclosure Accessories
Spare/Replacement Parts
Contract Manufacturing Services
Industries
All Industries
Battery Energy Storage Systems
Kiosks, ATMs & Smart Lockers
Medical Technology
Wastewater & Water Treatment
Transportation
Industrial Manufacturing
Hazardous Locations
Food & Beverage
Military & Avionics
Infrastructure
Security Detection & Surveillance
Sizing
Resources
Cooling Solutions Blog
MyKooltronic Customer Portal
Product Documentation
Whitepapers
An Intro to Closed Loop Cooling
Quality & Compliance Certficates ►
ISO 9001:2015 Certificate
UL Client Test Data Program Certificate
ROHS 3 Compliance Statement
REACH Declaration
Kooltronic Quality Policy
Conflict Minerals Report
Credit Application
Credit Reference Form
About Us
About Kooltronic
News & Announcements
Eco-Friendly Practices
Interactive Timeline
Virtual Tour
Careers with Kooltronic
Contact Us
Send Us a Message
Sales Team
After Sale Kare (ASK)
RFQ Cart
MyKooltronic
KPHE39 Water-to-Air
Panel-Mounted Heat Exchangers
Close
Image 1 of 1
Maximize image
Restore image
NEMA
TYPE 12 AND 3R
MAINTAINED
$3,195
.00
Update Qty
Show Price Breaks ▼
Hide Price Breaks ▲
Quantity
Price Each
1-1
$3,195.00
2-4
$3,132.00
5-9
$2,876.00
10-24
$2,684.00
25-49
$2,493.00
50-99
$2,397.00
100+
$2,287.00
16 in stock. Ships in 2-3 business days.
Order 1 more and pay $3,132.00 each
Select Model Type
Electrical (Volts):
115
230
Model
Volts
Power
Maximum
Inlet
Water
Temp. °F
Performance
Watts/°F
(Air In)
Approx
Weight
lbs.
(kg.)
Amps
Watts
1GPM
2GPM
KPHE39
115
2
235
85
68/109
79/142
50
K2PHE39
230
1
235
85
68/109
79/142
50
60 Hz. operation. For 50 Hz. operation, consult Kooltronic.
TECHNICAL DATA
Model Number
Volts
Performance Watts/°F (Air In)
1GPM
2GPM
KPHE39
115
68/109
79/142
Power, Amps: 2
Power, Watts: 235
Max. Inlet Water Temp. °F: 85
Approx. weight: 50 lbs. (23 kg)
K2PHE39
230
68/109
79/142
Power, Amps: 1
Power, Watts: 235
Max. Inlet Water Temp. °F: 85
Approx. weight: 50 lbs. (23 kg)
60 Hz. operation. For 50 Hz. operation, consult Kooltronic.
Standard Features
Accessories & Options
Airflow Diagram
Performance
Arrangement
Similar Models
Documents
•
Baked Powder Finish
Heavy-duty steel shell with powder-baked finish (ANSI 61 gray). Custom color options are available.
•
Precision ball bearing motors
•
Closed-Loop Cooling
The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
•
Heavy-Duty Steel Shell with Baked Powder Finish
•
NEMA 12 & 3R Ratings Maintained (UL50)
All units are fully gasketed for tight, leakproof installation, in compliance with the NEMA 12 and 3R Enclosure Ratings.
•
Six-Foot [1.8m] (minimum) 3-Wire Power Cord
•
UL/CUL Listed
•
Automatic Water Flow Control
This control consists of a temperature control thermostat and a solenoid valve. When the temperature within the enclosure drops below the thermostat set point due to decreased load or decreasing water temperature, the thermostat closes the solenoid valve. When the temperature increases to the set point (plus a differential) the thermostat opens the solenoid valve and the supply water cools the enclosure. In most models the Automatic Water Flow Control also includes a bypass flow meter which allows a small amount of water (0.25 gpm) to pass through the heat exchanger at all times.
•
Excess Heat Detector
•
High Water Level Detector
Closes water-supply valve to prevent flooding if excess water accumulates in the drain pan. Signal circuit activates a user-supplied warning device. The low voltage power for the signal circuit is supplied by the user.
•
Internal Corrosion Protection
This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
•
Lifting Eyes
Heavy-gauge steel lifting eyes, attached to the side panels, assist in positioning units.
•
Low Airflow Detector
Similar to the Airflow Switch shown in the Blower Accessories Section, the switch is installed in a suitable location in the air conditioner to detect loss of airflow, and sends a signal to a terminal block, through which user-installed wiring and warning devices are activated.
•
Mounting Hinge
(Left-hand or Right-hand) Allows the air conditioner itself to be used as a cabinet door. (Caution: The cabinet must be able to support the full weight of the unit in open position.) Specify left-hand (LH) or right-hand (RH), determined by facing the mounting side of the unit.
•
Other voltages and frequencies
•
Parallel Water Connections
•
Special materials or finishes
•
Special motors~ line cords or connectors
•
Stainless or Aluminum Shell
•
Temperature Alarm
A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.
•
Water Hook-up Opposite Side
Click on image for larger view
Close
Image 1 of 1
Maximize image
Restore image
Dimensions, inches [mm], are for reference only and subject to change.
Performance Charts for this product family are not currently available. Please contact Customer Service for more information.
Click on image for larger view
Close
Image 1 of 1
Maximize image
Restore image
Dimensions, inches [mm], are for reference only and subject to change.
Dimensions, inches [mm], are for reference only and subject to change.
Model
Guideline
Dimensions
(H x W x D)*
CFM @0" S.P.
KPHE32
32.00 x 15.50 x 10.95
0
*See model specifics for drawings, dimensions, mounting or cutout plans.
Data Sheet
KPHE39 Product Data Sheet [81Kb]
GA Drawing
KPHE39 General Arrangement Drawing (Discontinued) [119Kb]
KPHE39-33 General Arrangement Drawing (Discontinued) [129Kb]
KPHE39-XX50 General Arrangement Drawing (Discontinued) [79Kb]
Literature
Condensate Evaporator Kits [241Kb]
Increasing the Lifespan and Reliability of Electrical Components [212Kb]
Kooltronic Custom Capabilities Flyer [2194Kb]
Kooltronic Custom Cooling Medical Flyer [211Kb]
Kooltronic Design Guide/Catalog (220 pages) [229400Kb]
Kooltronic Refrigeration System Manufacturing [55Kb]
Kooltronic Standard Warranty [55Kb]
Kooltronic Unit Longevity Press Release [167Kb]
NEMA Enclosure Ratings [91Kb]
Short-Form Catalog (16 pages) [897Kb]
Airflow Switch Data Sheet [159Kb]
Heat Exchanger Quick-Sheet [90Kb]
Laboratory Environmental Testing Services [157Kb]
Powder Paint Application Facilities Flyer [165Kb]
Operator's Manual
KLLC100 Lead-Lag Controller (Discontinued) [38Kb]
KLLC480 Lead-Lag Controller [79Kb]
KPHE36, 39 & 40A Operator's Manual (Discontinued) [108Kb]
Wiring Diagram
KPHE39 Wiring Diagram (Discontinued) [47Kb]
KPHE39-29, KPHE39-30, KPHE39-X130 Wiring Diagram (Discontinued) [62Kb]
KPHE39-33 Wiring Diagram (Discontinued) [56Kb]
KPHE39-35 Wiring Diagram (Discontinued) [66Kb]
KPHE39CDM Wiring Diagram (Discontinued) [62Kb]
KPHE39CDM Wiring Diagram (Discontinued) [55Kb]
KPHE39CDMW Wiring Diagram (Discontinued) [58Kb]
KPHE39CDMW Wiring Diagram (Discontinued) [59Kb]
KPHE39CW Wiring Diagram (Discontinued) [51Kb]
KPHE39CW Wiring Diagram (Discontinued) [50Kb]
KPHE39DW Wiring Diagram (Discontinued) [49Kb]